Under fire conditions Flamex Two intumesces, forming a foam-like structure which insulates and provides a barrier to hot gas and flame. Flamex Two high performance sealant forms a tough, flexible rubber-like seal with a movement accommodation factor of 25% for high movement situations. Flamex Two is suitable for expansion joints in building superstructures and may be used in both internal and external joints. Flamex Two can be used in joints from 5 mm up to 50 mm wide, with a minimum depth of 12mm in all circumstances.For non-trafficked movement joints the width of sealant should be twice the depth, subject to a minimum depth of 12 mm. For trafficked movement joints, sealant depth should be equal to the width subject to a minimum depth of 12mm. The use of a surface primer is always required.